Solar. Storage. Charging. Connected.Global project enquiries | English
Home/Products/EV Charging Stations/Split EV Charging Systems with Shared Power Cabinets
EV Charging Stations

Split EV Charging Systems with Shared Power Cabinets

Separate central power conversion from vehicle-facing charging terminals. Compare 480–2400kW cabinet configurations and define terminal count, individual limits and matrix power allocation for the site.

System power options
480–2400kW
Architecture
Power cabinet + charging terminals
Power allocation
Matrix distribution
Model-specific configurationProject selection support
PRODUCT OVERVIEW

Select the right product for your application.

Explore features, suitable applications, installation conditions and equipment interfaces before comparing the model specifications.

A split EV charging system places power conversion in central cabinets and distributes DC power to separate terminals. This arrangement lets the station layout be planned around vehicle positions while cabinet capacity and terminal output limits are selected together.

01

Key features

  • Six system capacities — 480 / 720 / 960 / 1280 / 1920 / 2400kW cabinet ratings.
  • Distributed terminals — Central power cabinets serve separate charging positions.
  • Matrix allocation — Site power can be allocated across the configured terminals.
  • Cabinet-specific dimensions — Cabinet width changes with rated system capacity.
02

Where this product fits

  • Fleet depots with multiple charging positions.
  • Commercial hubs coordinating shared station power.
  • Sites planning a defined initial installation and later expansion review.
03

How to select the right configuration

Compare total cabinet power with the expected concurrent charging demand. Specify terminal count, connector type and per-output requirements, then review the matrix allocation strategy. The aggregate system current must not be treated as the current available at each terminal.

04

Installation and site requirements

Plan cabinet locations, terminal positions, DC cable routes, communications and service access on a site drawing. Check foundation, cable distance and sizing, vehicle circulation and AC distribution. Cabinet dimensions vary with system rating.

05

Equipment compatibility

Coordinate the approved cabinet-terminal combination, communication and control logic. Match vehicle voltage and current requirements to terminal limits. Future terminals require a review of hardware, cabling, power modules and control capacity.

06

Equipment and delivery scope

Define power cabinet quantities and ratings, terminal count, connectors, interconnection cables and station controls in one schedule. Confirm site distribution, civil works, installation and commissioning responsibilities rather than assuming they are included with the cabinets.

CONFIGURATION & SPECIFICATIONS

System components and model specifications.

Compare the available ratings and configurations. Confirm electrical interfaces, installation requirements and the equipment schedule for your site.

Discuss your configuration →

Plan cabinet access, terminal locations, vehicle circulation, cable routes and the station power budget as one design.

01

Power cabinet

Select capacity, AC connection and distribution equipment.

02

Charging terminals

Confirm terminal count, connector standard and individual limits.

03

Controls

Agree allocation strategy, communications and station monitoring.

TECHNICAL SPECIFICATIONS

Model-by-model specifications.

Select a model to review its electrical, control and installation data. Values apply to the named configuration.

480kW

Cabinet & electrical

ModelCY-DMA1-40C-480
Rated system power480kW
Dimensions (W × D × H)1080 × 1050 × 2000mm
Input supplyThree-phase, five-wire; 380V AC ±15%
Input frequency50Hz ±1Hz
Rated DC voltage1000V DC
Rated aggregate output current480A
Output voltage range200–1000V
Power allocationMatrix distribution
Voltage regulation≤±0.5%
Current regulation≤±1%
Charging efficiency≥95% at 50–100% rated load; ≥88% at 20–50% rated load
Power factor≥0.99 at 50–100% rated load
THD≤5% at 50–100% rated load

Installation & control

MountingFloor standing
Cable routingBottom entry and exit
CoolingAir cooling
Network4G / Ethernet
Operating / storage temperature−40 to +60°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
ProtectionConnector-temperature and contactor monitoring; voltage, overload, short-circuit, earth, insulation, surge and leakage protection

720kW

Cabinet & electrical

ModelCY-DMA1-40C-720
Rated system power720kW
Dimensions (W × D × H)1280 × 1050 × 2000mm
Input supplyThree-phase, five-wire; 380V AC ±15%
Input frequency50Hz ±1Hz
Rated DC voltage1000V DC
Rated aggregate output current720A
Output voltage range200–1000V
Power allocationMatrix distribution
Voltage regulation≤±0.5%
Current regulation≤±1%
Charging efficiency≥95% at 50–100% rated load; ≥88% at 20–50% rated load
Power factor≥0.99 at 50–100% rated load
THD≤5% at 50–100% rated load

Installation & control

MountingFloor standing
Cable routingBottom entry and exit
CoolingAir cooling
Network4G / Ethernet
Operating / storage temperature−40 to +60°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
ProtectionConnector-temperature and contactor monitoring; voltage, overload, short-circuit, earth, insulation, surge and leakage protection

960kW

Cabinet & electrical

ModelCY-DMA1-40C-960
Rated system power960kW
Dimensions (W × D × H)2160 × 1050 × 2000mm
Input supplyThree-phase, five-wire; 380V AC ±15%
Input frequency50Hz ±1Hz
Rated DC voltage1000V DC
Rated aggregate output current960A
Output voltage range200–1000V
Power allocationMatrix distribution
Voltage regulation≤±0.5%
Current regulation≤±1%
Charging efficiency≥95% at 50–100% rated load; ≥88% at 20–50% rated load
Power factor≥0.99 at 50–100% rated load
THD≤5% at 50–100% rated load

Installation & control

MountingFloor standing
Cable routingBottom entry and exit
CoolingAir cooling
Network4G / Ethernet
Operating / storage temperature−40 to +60°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
ProtectionConnector-temperature and contactor monitoring; voltage, overload, short-circuit, earth, insulation, surge and leakage protection

1280kW

Cabinet & electrical

ModelCY-DMA1-40C-1280
Rated system power1280kW
Dimensions (W × D × H)2560 × 1050 × 2000mm
Input supplyThree-phase, five-wire; 380V AC ±15%
Input frequency50Hz ±1Hz
Rated DC voltage1000V DC
Rated aggregate output current1280A
Output voltage range200–1000V
Power allocationMatrix distribution
Voltage regulation≤±0.5%
Current regulation≤±1%
Charging efficiency≥95% at 50–100% rated load; ≥88% at 20–50% rated load
Power factor≥0.99 at 50–100% rated load
THD≤5% at 50–100% rated load

Installation & control

MountingFloor standing
Cable routingBottom entry and exit
CoolingAir cooling
Network4G / Ethernet
Operating / storage temperature−40 to +60°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
ProtectionConnector-temperature and contactor monitoring; voltage, overload, short-circuit, earth, insulation, surge and leakage protection

1920kW

Cabinet & electrical

ModelCY-DMA1-40C-1920
Rated system power1920kW
Dimensions (W × D × H)2760 × 1050 × 2000mm
Input supplyThree-phase, five-wire; 380V AC ±15%
Input frequency50Hz ±1Hz
Rated DC voltage1000V DC
Rated aggregate output current1920A
Output voltage range200–1000V
Power allocationMatrix distribution
Voltage regulation≤±0.5%
Current regulation≤±1%
Charging efficiency≥95% at 50–100% rated load; ≥88% at 20–50% rated load
Power factor≥0.99 at 50–100% rated load
THD≤5% at 50–100% rated load

Installation & control

MountingFloor standing
Cable routingBottom entry and exit
CoolingAir cooling
Network4G / Ethernet
Operating / storage temperature−40 to +60°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
ProtectionConnector-temperature and contactor monitoring; voltage, overload, short-circuit, earth, insulation, surge and leakage protection

2400kW

Cabinet & electrical

ModelCY-DMA1-40C-2400
Rated system power2400kW
Dimensions (W × D × H)3960 × 1050 × 2000mm
Input supplyThree-phase, five-wire; 380V AC ±15%
Input frequency50Hz ±1Hz
Rated DC voltage1000V DC
Rated aggregate output current2400A
Output voltage range200–1000V
Power allocationMatrix distribution
Voltage regulation≤±0.5%
Current regulation≤±1%
Charging efficiency≥95% at 50–100% rated load; ≥88% at 20–50% rated load
Power factor≥0.99 at 50–100% rated load
THD≤5% at 50–100% rated load

Installation & control

MountingFloor standing
Cable routingBottom entry and exit
CoolingAir cooling
Network4G / Ethernet
Operating / storage temperature−40 to +60°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
ProtectionConnector-temperature and contactor monitoring; voltage, overload, short-circuit, earth, insulation, surge and leakage protection
Quick configuration comparison
COMPARE CONFIGURATIONS

Models & specification options

Choose a configuration as the starting point for your enquiry. Values in each row apply to that configuration; ranges indicate model options.

ConfigurationPower optionsArrangementElectrical / installation notesEnquiry
Split charging system480 / 720 / 960 / 1280 / 1920 / 2400kWPower cabinet + terminals; matrix allocation200–1000V DC; AC380V ±15%Select configuration →

Final model, options, supply scope and destination-specific documentation are confirmed in the technical quotation. Request model documentation →

SELECTION RESOURCES

Plan the equipment around your project.

Use the related guidance to prepare a clear equipment schedule and review the configuration with your project team.

RELATED PROJECT APPLICATIONS

See the equipment in context.

Explore project references →

Explore documented applications related to this product category. Selected equipment models and project scope are described on each project page.

PRODUCT QUESTIONS

Details that help you decide.

Answers about model selection, equipment options and the scope of your order.

Frequently asked questions

How is split charging different from an integrated charger?

The power cabinet and vehicle-facing terminals are separate. The layout and shared allocation are planned across the system instead of treating each terminal as a standalone full-power charger.

Can every terminal receive the full cabinet rating?

No. Cabinet capacity is an aggregate system rating. Terminal limits, vehicle demand and the allocation strategy determine the power at each output.

Can more terminals be added later?

Expansion requires confirmation of the approved cabinet-terminal arrangement, control capacity, available modules, cable design and site power. Specify the intended expansion plan at the design stage.

What is needed for a terminal layout?

Provide the parking plan, vehicle sizes, connector positions, cable routes, desired simultaneous sessions and the available transformer and AC distribution capacity.

PRODUCT ENQUIRY

Plan your equipment configuration.

Tell us the project country, power or capacity requirement and intended application. Add the installation conditions and compatible equipment where available.

Split EV Charging Systems with Shared Power Cabinets

Separate central power conversion from vehicle-facing charging terminals. Compare 480–2400kW cabinet configurations and define terminal count, individual limits and matrix power allocation for the site.

You can prepare and download your project brief. Enquiry delivery is not configured, so no information will be sent.

Only share information relevant to this enquiry. See our privacy notice.

LET'S BUILD YOUR ENERGY SYSTEM

Start with your project.
Find the right configuration.

Discuss your application