Solar. Storage. Charging. Connected.Global project enquiries | English
Home/Products/EV Charging Stations/Dual-Output DC Fast Charging Stations
EV Charging Stations

Dual-Output DC Fast Charging Stations

DC fast charging for commercial parking and public charging sites. Compare 80–160kW CCS2 configurations and 120–240kW series options by voltage, current and simultaneous output capability.

Rated power options
120–240kW
Charging outputs
Dual gun
Cooling
Air cooling
Model-specific configurationProject selection support
PRODUCT OVERVIEW

Select the right product for your application.

Explore features, suitable applications, installation conditions and equipment interfaces before comparing the model specifications.

A DC fast charging station converts AC site power for direct charging of the vehicle battery. Rated station power is only one selection factor: vehicle voltage, current acceptance and the sharing strategy between outputs determine the charging capability available in use.

01

Key features

  • Multiple DC power classes — 80–160kW CCS2 configurations and 120–240kW series configurations.
  • Two charging outputs — Dual-gun equipment with model-dependent output allocation.
  • Different voltage ranges — 200–750V, 200–1000V and 300–1100V entries belong to different configurations.
  • Station operation — Touch-screen, user access and network functions depend on the selected version.
02

Where this product fits

  • Commercial parking with shorter charging windows.
  • Public charging stations serving compatible electric vehicles.
  • Business sites planning two simultaneous charging connections.
03

How to select the right configuration

Check the fleet or customer vehicle voltage range and connector standard. Compare the required turnaround time with vehicle charge acceptance, then review station power and simultaneous output limits. The different voltage windows in the model table belong to their named configurations.

04

Installation and site requirements

Provide the three-phase supply details, transformer capacity, site layout and proposed charger location. Plan protection, earthing, foundation, cable routing, service access and vehicle movement. Confirm environmental ratings for the final model.

05

Equipment compatibility

Review the charger connector, communication interface and vehicle charging requirements together. If a management or payment platform is needed, confirm the protocol and integration scope for the ordered version before procurement.

06

Equipment and delivery scope

Specify the model, connector count, cable arrangement, access method and network functions. Identify any external transformer, distribution, payment integration or civil work separately. Confirm installation documents and commissioning responsibilities in the quotation.

CONFIGURATION & SPECIFICATIONS

System components and model specifications.

Compare the available ratings and configurations. Confirm electrical interfaces, installation requirements and the equipment schedule for your site.

Discuss your configuration →

Match charger output to the vehicles, AC connection and simultaneous charging plan. Confirm the connector, platform protocol, enclosure, thermal design and operating-temperature limits in the final model documentation.

01

Vehicle connection

Select connector, DC voltage range and current capability.

02

Site connection

Review three-phase supply, transformer capacity and protection.

03

Management

Confirm access, payment and charging-platform integration.

TECHNICAL SPECIFICATIONS

Model-by-model specifications.

Select a model to review its electrical, control and installation data. Values apply to the named configuration.

80–160kW / CCS2

Electrical

Model familyChangyuan80-160kW
Output power options80–160kW
Connector standardCCS2
Charging outputs2
AC input380V AC ±15%, three phase
Frequency50 / 60Hz
DC output voltage200–750V DC
Power allocationDynamic intelligent allocation
Overall efficiency≥94%

Operation

Display10-inch touch screen
AccessCard, QR, app and plug-and-charge options
CoolingForced-air cooling
Storage temperature−40 to +70°C

120kW

Electrical

Model seriesCDZ-120kW
Rated power options120kW
AC input380V AC ±20%
Input frequency50–60Hz
DC voltage200–1000V DC (60kW module)
Output current10–400A
Charging efficiency≥97%, listed
Metering accuracyClass 1
Voltage regulation≤±1%
Ripple factor≤±0.5%
Harmonic current≤5%

Installation

Dimensions (W × H × D)800 × 1700 × 540mm
InstallationFloor mounted
Cable routingBottom entry / bottom exit
Cable length5m; configurable
CoolingAir cooling
Humidity5–95% RH, non-condensing
Altitude≤4000m

160 / 180kW

Electrical

Model seriesCDZ-160/180kW
Rated power options160 / 180kW
AC input380V AC ±20%
Input frequency50–60Hz
DC voltage200–1000V DC (40kW module)
Output current10–500A
Charging efficiency≥97%, listed
Metering accuracyClass 1
Voltage regulation≤±1%
Ripple factor≤±0.5%
Harmonic current≤5%

Installation

Dimensions (W × H × D)800 × 1700 × 540mm
InstallationFloor mounted
Cable routingBottom entry / bottom exit
Cable length5m; configurable
CoolingAir cooling
Humidity5–95% RH, non-condensing
Altitude≤2000m

200 / 240kW

Electrical

Model seriesCDZ-200/240kW
Rated power options200 / 240kW
AC input380V AC ±20%
Input frequency50–60Hz
DC voltage300–1100V DC
Output current250A
Charging efficiency≥97%, listed
Metering accuracyClass 1
Voltage regulation≤±1%
Ripple factor≤±0.5%
Harmonic current≤5%

Installation

Dimensions (W × H × D)800 × 1700 × 540mm
InstallationFloor mounted
Cable routingBottom entry / bottom exit
Cable length5m; configurable
CoolingAir cooling
Humidity5–95% RH, non-condensing
Altitude≤4000m
Quick configuration comparison
COMPARE CONFIGURATIONS

Models & specification options

Choose a configuration as the starting point for your enquiry. Values in each row apply to that configuration; ranges indicate model options.

ConfigurationPower optionsArrangementElectrical / installation notesEnquiry
Dual-gun DC station120–240kWDual gun; air coolingAC380V ±20%; floor mountedSelect configuration →

Final model, options, supply scope and destination-specific documentation are confirmed in the technical quotation. Request model documentation →

SELECTION RESOURCES

Plan the equipment around your project.

Use the related guidance to prepare a clear equipment schedule and review the configuration with your project team.

RELATED PROJECT APPLICATIONS

See the equipment in context.

Explore project references →

Explore documented applications related to this product category. Selected equipment models and project scope are described on each project page.

PRODUCT QUESTIONS

Details that help you decide.

Answers about model selection, equipment options and the scope of your order.

Frequently asked questions

Can both connectors deliver the full station rating?

Station power and per-connector power are different ratings. The allocation depends on the selected configuration and the connected vehicles; request the simultaneous output schedule.

Will a higher rated charger always shorten a session?

No. Vehicle voltage, current acceptance, battery state and temperature can limit power. Compare the charger with the vehicles and charging window.

Are all listed voltage ranges available on one unit?

No. The table separates configurations with different voltage windows. Select a specific model against the intended vehicles.

Can the charger connect to our charging platform?

Provide the platform and protocol requirements. Network connectivity and backend integration must be confirmed for the selected hardware and software version.

PRODUCT ENQUIRY

Plan your equipment configuration.

Tell us the project country, power or capacity requirement and intended application. Add the installation conditions and compatible equipment where available.

Dual-Output DC Fast Charging Stations

DC fast charging for commercial parking and public charging sites. Compare 80–160kW CCS2 configurations and 120–240kW series options by voltage, current and simultaneous output capability.

You can prepare and download your project brief. Enquiry delivery is not configured, so no information will be sent.

Only share information relevant to this enquiry. See our privacy notice.

LET'S BUILD YOUR ENERGY SYSTEM

Start with your project.
Find the right configuration.

Discuss your application