Solar. Storage. Charging. Connected.Global project enquiries | English
Home/Products/EV Charging Stations/DC Charging Stations for Electric Truck Fleets
EV Charging Stations

DC Charging Stations for Electric Truck Fleets

Plan depot charging around vehicle voltage, route energy and turnaround time. Compare 320/400/600kW charging configurations and 640/700/800kW four-connector options for heavy-duty fleet projects.

Power options
320 / 400 / 600 / 640 / 700 / 800kW
Output voltage
200–1000V DC
Installation
Floor mounted
Model-specific configurationProject selection support
PRODUCT OVERVIEW

Select the right product for your application.

Explore features, suitable applications, installation conditions and equipment interfaces before comparing the model specifications.

Electric truck charging needs a coordinated vehicle, charger and site-power plan. This range covers integrated charging configurations and higher-power four-connector versions. Choose a model using the trucks’ charging interfaces and the depot’s concurrent demand rather than station power alone.

01

Key features

  • Six power ratings — 320, 400 and 600kW integrated chargers plus 640, 700 and 800kW four-connector versions.
  • Wide DC voltage window — 200–1000V DC output supports vehicle matching across different battery voltages.
  • Power allocation matters — Four-connector versions list 500A per connector and a separate aggregate current limit.
  • Connected operation — Touch-screen operation, Ethernet and model-dependent mobile network options.
02

Where this product fits

  • Logistics depots with scheduled vehicle arrivals and departures.
  • Commercial truck fleets comparing charging during layovers.
  • Heavy-duty vehicle sites planning several charging connections.
03

How to select the right configuration

Share truck battery voltage, connector type, current limit, arrival state of charge and departure target. Estimate energy needed during each dwell period, then review overlapping sessions and transformer capacity. Compare per-connector and aggregate limits for each candidate model.

04

Installation and site requirements

Map truck turning paths, parking orientation and connector reach before locating equipment. Confirm the AC connection, transformer and distribution ratings, cable routes, foundation and service access. Select enclosure and environmental limits for the depot conditions.

05

Equipment compatibility

The charger output window must match the truck battery and charging interface. Four-connector power allocation should be checked against simultaneous vehicle requests. Agree network, fleet scheduling and any external energy-management interface as part of the configuration.

06

Equipment and delivery scope

Record station rating, connector arrangement, cable specification, network functions and allocation strategy. Define the transformer, distribution, protection, civil work and commissioning scope separately from the charger where applicable.

CONFIGURATION & SPECIFICATIONS

System components and model specifications.

Compare the available ratings and configurations. Confirm electrical interfaces, installation requirements and the equipment schedule for your site.

Discuss your configuration →

Coordinate the charging equipment with depot transformer capacity, vehicle battery voltage, dwell windows and simultaneous demand. Confirm the connector standard and power allocation before selecting the site equipment.

01

Vehicle interface

Check connector, voltage and current acceptance for each truck.

02

Power supply

Match transformer, AC distribution, protection and cable sizing.

03

Station controls

Agree user access, charging modes, networking and platform interfaces.

TECHNICAL SPECIFICATIONS

Model-by-model specifications.

Select a model to review its electrical, control and installation data. Values apply to the named configuration.

320kW

Electrical

ModelCDZ-(320)kW
Rated equipment power320kW
Module power40kW
AC input380V AC ±20%
Input frequency45–65Hz
DC output voltage200–1000V
Cable length7m
Metering accuracyClass 0.5
Charging efficiency≥94.5% at 50–100% load
Power factor≥0.99
Current harmonics (THD)≤5% above 50% load
Voltage regulation≤±0.5%
Current regulation≤±1%
Single-connector output current0–250A

Controls & communication

Display7-inch LCD colour touch screen; LED status indication
NetworkEthernet; 2G / 3G / 4G
Charging modesFull charge, selected energy, selected amount or selected time
Access / paymentCard, app or QR options
Protection functionsConnector temperature monitoring; over/under-voltage, overcurrent, short-circuit, earth, insulation and leakage protection; emergency stop

Installation

MountingFloor standing
Cable routingBottom entry / top exit
Dimensions (W × H × D)1050 × 1850 × 900mm
CoolingForced-air cooling
Noise≤70dB
Relative humidity5–95% RH, non-condensing
Altitude<4000m

400kW

Electrical

ModelCDZ-(400)kW
Rated equipment power400kW
Module power50kW
AC input380V AC ±20%
Input frequency45–65Hz
DC output voltage200–1000V
Cable length7m
Metering accuracyClass 0.5
Charging efficiency≥94.5% at 50–100% load
Power factor≥0.99
Current harmonics (THD)≤5% above 50% load
Voltage regulation≤±0.5%
Current regulation≤±1%
Single-connector current options0–250A / 300A

Controls & communication

Display7-inch LCD colour touch screen; LED status indication
NetworkEthernet; 2G / 3G / 4G
Charging modesFull charge, selected energy, selected amount or selected time
Access / paymentCard, app or QR options
Protection functionsConnector temperature monitoring; over/under-voltage, overcurrent, short-circuit, earth, insulation and leakage protection; emergency stop

Installation

MountingFloor standing
Cable routingBottom entry / top exit
Dimensions (W × H × D)1050 × 1850 × 900mm
CoolingForced-air cooling
Noise≤70dB
Relative humidity5–95% RH, non-condensing
Altitude<4000m

600kW

Electrical

ModelCDZ-(600)kW
Rated equipment power600kW
Module power60kW
AC input380V AC ±20%
Input frequency45–65Hz
DC output voltage200–1000V
Cable length7m
Metering accuracyClass 0.5
Charging efficiency≥94.5% at 50–100% load
Power factor≥0.99
Current harmonics (THD)≤5% above 50% load
Voltage regulation≤±0.5%
Current regulation≤±1%

Controls & communication

Display7-inch LCD colour touch screen; LED status indication
NetworkEthernet; 2G / 3G / 4G
Charging modesFull charge, selected energy, selected amount or selected time
Access / paymentCard, app or QR options
Protection functionsConnector temperature monitoring; over/under-voltage, overcurrent, short-circuit, earth, insulation and leakage protection; emergency stop

Installation

MountingFloor standing
Cable routingBottom entry / top exit
Dimensions (W × H × D)1050 × 1850 × 900mm
CoolingForced-air cooling
Noise≤70dB
Relative humidity5–95% RH, non-condensing
Altitude<4000m

640kW / 4 guns

Electrical

ModelCDZ-640/4
Rated equipment power640kW
Power module50kW typical
Number of connectors4
Maximum current per connector500A
Listed aggregate current limit1000A across four outputs; allocation depends on configuration
AC input380V AC ±15%
Input frequency50Hz ±10%
DC output voltage200–1000V DC
Charging efficiency≥95%
Power factor≥0.99 above 50% load
Output voltage error≤±0.5%
Output current error≤±1%
Voltage regulation≤±0.5%
Current regulation≤±1%
Harmonic content≤5%
Insulation resistance≥20MΩ
Energy meteringClass 1.0

Controls & protection

Display7-inch touch screen
NetworkEthernet; optional 4G
Charging modesAutomatic full charge, time, energy or amount
Access optionsIC card, QR, VIN or password
Protection functionsConnector temperature monitoring; over/under-voltage, overcurrent, short-circuit, earth, insulation and leakage protection; emergency stop

Installation & environment

Dimensions (W × D × H)1050 × 1180 × 2000mm
Cable length7m
CoolingAir cooling + air-conditioning refrigeration
InstallationFloor mounted; indoor or outdoor site design
Operating temperature−20 to +50°C
Storage temperature−40 to +70°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
Noise≤65dB

700kW / 4 guns

Electrical

ModelCDZ-700/4
Rated equipment power700kW
Power module50kW typical
Number of connectors4
Maximum current per connector500A
Listed aggregate current limit1000A across four outputs; allocation depends on configuration
AC input380V AC ±15%
Input frequency50Hz ±10%
DC output voltage200–1000V DC
Charging efficiency≥95%
Power factor≥0.99 above 50% load
Output voltage error≤±0.5%
Output current error≤±1%
Voltage regulation≤±0.5%
Current regulation≤±1%
Harmonic content≤5%
Insulation resistance≥20MΩ
Energy meteringClass 1.0

Controls & protection

Display7-inch touch screen
NetworkEthernet; optional 4G
Charging modesAutomatic full charge, time, energy or amount
Access optionsIC card, QR, VIN or password
Protection functionsConnector temperature monitoring; over/under-voltage, overcurrent, short-circuit, earth, insulation and leakage protection; emergency stop

Installation & environment

Dimensions (W × D × H)1050 × 1180 × 2000mm
Cable length7m
CoolingAir cooling + air-conditioning refrigeration
InstallationFloor mounted; indoor or outdoor site design
Operating temperature−20 to +50°C
Storage temperature−40 to +70°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
Noise≤65dB

800kW / 4 guns

Electrical

ModelCDZ-800/4
Rated equipment power800kW
Power module50kW typical
Number of connectors4
Maximum current per connector500A
Listed aggregate current limit1000A across four outputs; allocation depends on configuration
AC input380V AC ±15%
Input frequency50Hz ±10%
DC output voltage200–1000V DC
Charging efficiency≥96%
Power factor≥0.99 above 50% load
Output voltage error≤±0.5%
Output current error≤±1%
Voltage regulation≤±0.5%
Current regulation≤±1%
Harmonic content≤5%
Insulation resistance≥20MΩ
Energy meteringClass 1.0

Controls & protection

Display7-inch touch screen
NetworkEthernet; optional 4G
Charging modesAutomatic full charge, time, energy or amount
Access optionsIC card, QR, VIN or password
Protection functionsConnector temperature monitoring; over/under-voltage, overcurrent, short-circuit, earth, insulation and leakage protection; emergency stop

Installation & environment

Dimensions (W × D × H)1050 × 1180 × 2000mm
Cable length7m
CoolingAir cooling + air-conditioning refrigeration
InstallationFloor mounted; indoor or outdoor site design
Operating temperature−20 to +50°C
Storage temperature−40 to +70°C
Humidity5–95% RH, non-condensing
Altitude≤2000m
Noise≤65dB
Quick configuration comparison
COMPARE CONFIGURATIONS

Models & specification options

Choose a configuration as the starting point for your enquiry. Values in each row apply to that configuration; ranges indicate model options.

ConfigurationPower optionsArrangementElectrical / installation notesEnquiry
DC truck charger320 / 400 / 600kWFloor mounted200–1000V DC; AC380V ±20%Select configuration →
CDZ-640/4 / 700/4 / 800/4640 / 700 / 800kW4 connectors200–1000V DC; AC380V ±15%Select configuration →

Final model, options, supply scope and destination-specific documentation are confirmed in the technical quotation. Request model documentation →

SELECTION RESOURCES

Plan the equipment around your project.

Use the related guidance to prepare a clear equipment schedule and review the configuration with your project team.

RELATED PROJECT APPLICATIONS

See the equipment in context.

Explore project references →

Explore documented applications related to this product category. Selected equipment models and project scope are described on each project page.

PRODUCT QUESTIONS

Details that help you decide.

Answers about model selection, equipment options and the scope of your order.

Frequently asked questions

Which configurations have four connectors?

The CDZ-640/4, CDZ-700/4 and CDZ-800/4 configurations list four connectors. Check the model table for their aggregate and per-connector limits.

Does an 800kW station supply 800kW to every truck?

No. The station rating is shared within the configuration’s output limits. Each truck is also limited by its voltage, current acceptance and charging conditions.

How do I estimate fleet charging demand?

Use energy needed per vehicle, dwell time and the number of overlapping sessions. Include the existing site load and supply limit when evaluating the depot power requirement.

What vehicle information should be included in an enquiry?

Provide truck models, battery voltage, charging connector and current limit, route energy, typical arrival state of charge, dwell time and concurrent vehicle count.

PRODUCT ENQUIRY

Plan your equipment configuration.

Tell us the project country, power or capacity requirement and intended application. Add the installation conditions and compatible equipment where available.

DC Charging Stations for Electric Truck Fleets

Plan depot charging around vehicle voltage, route energy and turnaround time. Compare 320/400/600kW charging configurations and 640/700/800kW four-connector options for heavy-duty fleet projects.

You can prepare and download your project brief. Enquiry delivery is not configured, so no information will be sent.

Only share information relevant to this enquiry. See our privacy notice.

LET'S BUILD YOUR ENERGY SYSTEM

Start with your project.
Find the right configuration.

Discuss your application