Solar. Storage. Charging. Connected.Global project enquiries | English
Home/Products/EV Charging Stations/AC EV Charging Stations for Home and Workplace Parking
EV Charging Stations

AC EV Charging Stations for Home and Workplace Parking

AC charging equipment for private, workplace and destination parking. Compare the 7kW single-output configuration with 7kW and 14kW series options, then match the connector and supply to the vehicle.

Power options
7kW / 14kW series
Installation
Wall or pedestal
Configuration
Single / dual gun options
Model-specific configurationProject selection support
PRODUCT OVERVIEW

Select the right product for your application.

Explore features, suitable applications, installation conditions and equipment interfaces before comparing the model specifications.

AC EV charging supplies the vehicle’s onboard charger. Parking duration, the vehicle’s AC acceptance limit and available building power determine the useful charging rate. Select the exact output arrangement and connector before comparing installation and network options.

01

Key features

  • 7kW single-output charging — The Type 1 configuration provides 32A AC output.
  • Dual-output series option — The CDZ-(14)kW series lists 7 / 14kW and two charging guns.
  • Touch-screen operation — 4.3-inch display with charging status and user access functions.
  • Network options — Ethernet, 4G and Wi-Fi are listed for the AC series.
02

Where this product fits

  • Private parking with regular overnight charging.
  • Workplace parking where vehicles remain for several hours.
  • Managed destination parking with planned charging access.
03

How to select the right configuration

Estimate the energy required during the normal parking period and check the vehicle onboard AC limit. Compare single- and dual-output arrangements against the number of parking spaces. Confirm the input voltage and current for the selected model rather than applying one configuration’s rating to the whole range.

04

Installation and site requirements

Choose wall or pedestal mounting after checking the support, parking layout and cable reach. Have the electrical designer specify the supply circuit, earthing and protection. For several chargers, assess simultaneous demand at the building connection.

05

Equipment compatibility

Match the ordered connector to the vehicles; the listed 7kW configuration uses Type 1. Confirm access control, network coverage and the required charging platform interface for the selected version. Available network options alone do not establish compatibility with every platform.

06

Equipment and delivery scope

Specify output count, connector, cable arrangement, mounting hardware and network functions. Agree whether a pedestal, external protection, metering or site installation is included. Record these items with the exact charger model in the quotation.

CONFIGURATION & SPECIFICATIONS

System components and model specifications.

Compare the available ratings and configurations. Confirm electrical interfaces, installation requirements and the equipment schedule for your site.

Discuss your configuration →

Select a single-output or dual-output unit according to parking dwell time, vehicle interface and the building supply. Multiple chargers require a site-level assessment of simultaneous demand and protection.

01

Vehicle

Confirm Type 1 or the ordered connector standard and onboard AC limit.

02

Installation

Choose wall or pedestal mounting, cable reach and protective devices.

03

Operation

Confirm user access, network coverage and charging management.

TECHNICAL SPECIFICATIONS

Model-by-model specifications.

Select a model to review its electrical, control and installation data. Values apply to the named configuration.

7kW / Type 1

Supplier configuration

ModelCDZ-7kW
Rated output7kW AC
Rated current32A
ConnectorType 1
Charging outlets1
AC input for this listing200–220V, single phase
Input frequency50–60Hz
Display4.3-inch touch screen
NetworkEthernet / 4G / Wi-Fi
Cable length3.5–5m; configurable
Dimensions (W × D × H)246 × 155 × 380mm
InstallationWall mounted
Operating temperature−30 to +65°C
Humidity5–95% RH, non-condensing

CDZ-(7)kW

Model data

Rated power7kW
Connector count1
AC input176–264V AC
Output current32A
Dimensions (W × D × H)246 × 155 × 380mm

Series operation

Display4.3-inch touch screen
Input frequency50–60Hz
NetworkEthernet / 4G / Wi-Fi
Cable options3.5m / 5m; configurable
CoolingNatural cooling
MountingWall or pedestal
Operating temperature−30 to +65°C
Humidity5–95% RH, non-condensing
Protection functionsOver/under-voltage, short-circuit, leakage, overcurrent, overheat, surge and emergency-stop protection

CDZ-(14)kW

Model data

Rated power options7 / 14kW
Connector count2
Output current options32 / 64A
Dimensions (W × D × H), as listed430 × 280 × 100mm

Series operation

Display4.3-inch touch screen
Input frequency50–60Hz
NetworkEthernet / 4G / Wi-Fi
Cable options3.5m / 5m; configurable
CoolingNatural cooling
MountingWall or pedestal
Operating temperature−30 to +65°C
Humidity5–95% RH, non-condensing
Protection functionsOver/under-voltage, short-circuit, leakage, overcurrent, overheat, surge and emergency-stop protection
Quick configuration comparison
COMPARE CONFIGURATIONS

Models & specification options

Choose a configuration as the starting point for your enquiry. Values in each row apply to that configuration; ranges indicate model options.

ConfigurationPower optionsArrangementElectrical / installation notesEnquiry
CDZ AC charging7kW / 14kW seriesSingle / dual gun optionsWall or pedestal; Ethernet, 4G, Wi-Fi optionsSelect configuration →

Final model, options, supply scope and destination-specific documentation are confirmed in the technical quotation. Request model documentation →

SELECTION RESOURCES

Plan the equipment around your project.

Use the related guidance to prepare a clear equipment schedule and review the configuration with your project team.

RELATED PROJECT APPLICATIONS

See the equipment in context.

Explore project references →

Explore documented applications related to this product category. Selected equipment models and project scope are described on each project page.

PRODUCT QUESTIONS

Details that help you decide.

Answers about model selection, equipment options and the scope of your order.

Frequently asked questions

Will a 7kW charger always charge a car at 7kW?

Actual power is limited by the charger, the vehicle’s onboard AC charger and the site supply. Vehicle settings and operating conditions can also reduce charging power.

Does a 14kW dual-output unit provide 14kW to each car?

Do not assume that rating applies to each output. Confirm the selected model’s total power and simultaneous per-output limits.

Can I choose wall or pedestal mounting?

Wall and pedestal arrangements are selected for the installation. Confirm the hardware, cable reach and supporting structure in the order scope.

What information is needed for several parking spaces?

Provide the number of spaces, typical parking time, vehicle connector types, site supply and required user-access or management functions.

PRODUCT ENQUIRY

Plan your equipment configuration.

Tell us the project country, power or capacity requirement and intended application. Add the installation conditions and compatible equipment where available.

AC EV Charging Stations for Home and Workplace Parking

AC charging equipment for private, workplace and destination parking. Compare the 7kW single-output configuration with 7kW and 14kW series options, then match the connector and supply to the vehicle.

You can prepare and download your project brief. Enquiry delivery is not configured, so no information will be sent.

Only share information relevant to this enquiry. See our privacy notice.

LET'S BUILD YOUR ENERGY SYSTEM

Start with your project.
Find the right configuration.

Discuss your application